top of page

Risultati di ricerca

51 items found for ""

  • Produzione Trasformatori Elettrici Resinati con Faston RG vm engineering

    / Products / Resinated Transformers / Resinated Transformers RG RG FASTON resin transformers We offer a wide range of resin-coated transformers. Thanks to their construction and being encapsulated with self-extinguishing epoxy resin, they have additional insulation, which improves the safety of the equipment. Our RG resin transformers are produced with the most varied characteristics such as: Primaries from 24 to 440 V Output voltages up to 4 secondaries Powers from 15 VA to 80 VA in reduced dimensions You can contact us for any specific project outside the standard and without the need for a minimum production batch. Products DA 15 A 40 VA DA 25 A 55 VA DA 40 A 60 VA 80VA

  • News | Trasformatori Elettrici Vm Engineering S.a.s. | Appiano Gentile

    News 02-01-2021 - New website published 04-01-2021 - Acquisition of the new domain www.vmtrafo.com 05-01-2021 - New direct chat platform added for technical and commercial info

  • EI84 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    EI 84 resin transformers from 70 to 100 VA / Products / Resinated Transformers / Resin Transformers EI / EI84 The items of the EI84 series are safety transformers, resistant to short circuits for construction or failure proof, for frequencies 50 / 60Hz, built according to the European standard EN61558-2-6 which guarantees a product of guaranteed quality and reliability as well as by use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production. The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. The peculiar features of the EI84 series: Wide range: pinout (your choice) primary voltage (optionally from 24V up to 440V) secondary voltage (optionally from 4V to 48V) · Possibility of distributing the total power up to 4 secondaries · Flexibility on the quantities that can be ordered Dimensions EI 30 EI 33 EI 38 10 PINS EI 38 12 PINS EI 40 EI 42 E I 48 EI 60 EI 66 EI 75 EI 84 ​ Menu Examples Documents ei84.pdf

  • EI40 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    EI 38 resin transformers from 3.2 to 5 VA (12 PINS) / Products / Resinated Transformers / Resinated Transformers EI / EI40 The items of the EI38 series are safety transformers, resistant to short circuits for construction or failure proof, for frequencies 50 / 60Hz, built according to the European standard EN61558-2-6 which guarantees a product of guaranteed quality and reliability as well as by use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. The peculiar characteristics of the EI38 series: · Excellent ratio between power and small size · Reduced drop between empty and load Wide range: pinout (your choice) primary voltage (optionally from 24V up to 440V) secondary voltage (optionally from 4V to 48V) · Possibility of distributing the total power up to 3 secondaries · Flexibility on the quantities that can be ordered Dimensions Menu EI 30 EI 33 EI 38 10 PINS EI 38 12 PINS EI 40 EI 42 E I 48 EI 60 EI 66 EI 75 EI 84 ​ Examples Documents

  • UI3010 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    Resinated Transformers UI 30/10 6 VA / Products / Resinated Transformers / Resinated Transformers UI / UI3010 Transformers mod. UI with a 2 X 115 V double primary circuit for 230 V series connection or 115 V + 115 V parallel connection. Possibility of fixing through pins or through 4 DIN 7971 2.4 mm holes. built according to the European standard EN61558-2-6 which guarantees a product of quality and reliability ensured not only by the use of excellent materials but also by the constant construction methodology and by our testing systems applied to the entire production. The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. Dimensions Documents Menu UI 30/7,5 UI 30/10 UI 30/16 UI 39/10 UI 39/13 UI 39/17 UI 39/21 UI 48/17 UI 48/26 ​ ​ Examples

  • EI75M | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    Transformers EI 75 FROM 30 TO 63 VA / Products / Control Transformers / EI75 The items of the EI75 MORSETTI series are control transformers, not resistant to short circuits with terminals mounted directly on the plastic reel, built according to the European standard EN61558-2-2 which guarantees a product of guaranteed quality and reliability as well as the use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production. To protect the transformers from overloads or short circuits, it is envisaged that protection devices (fuses) not supplied with the transformer, of the value indicated on the plate, must be used. The peculiar characteristics of the EI75 TERMINALS series: Primary voltage (optionally from 115V up to 400V) secondary voltage (optionally from 12V to 48V) · Flexibility on the quantities that can be ordered Dimensions Documents ei75M.pdf Menu EI 75 30/63 EI 75M 30/63 EI 75M2 30/63 EI 84 63/120 EI 84M 63/120 EI 84M2 63/120 EI 96 ​ ​ ​ Examples

  • EI96C | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    EI 96 transformers FROM 160 TO 250 VA / Products / Control Transformers / EI96 The items of the EI96 series are control transformers, not resistant to short circuits, built according to the European standard EN61558-2-2 which guarantees a product of quality and reliability ensured not only by the use of excellent materials but also by the constant method of construction and by our testing systems applied to the entire production. To protect the transformers from overloads or short circuits, it is envisaged that protection devices (fuses) not supplied with the transformer, of the value indicated on the plate, must be used. The peculiar characteristics of the EI96 series: Primary voltage (optionally from 115V up to 400V) secondary voltage (choice between 4V and 48V) Possibility of distributing the total power up to 3 secondary (low terminal holder), 4 secondary (high terminal holder) · Flexibility on the quantities that can be ordered Dimensions Menu EI 75 30/63 EI 75M 30/63 EI 75M2 30/63 EI 84 63/120 EI 84M 63/120 EI 84M2 63/120 EI 96 ​ ​ ​ Documents ei96.pdf Examples

  • EI 30 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    / Products / Resinated Transformers / Resinated Transformers EI / EI30 EI 30 EI 30/5 0.65 VA EI40 EI 42 EI48 EI 48/16 10VA EI 48/20 15VA EI 48/25 18.5VA EI54 EI60 EI66 EI75 EI84 EI 30 resin transformers from 1 to 2.8 VA The items of the EI30 series are safety transformers, resistant to short circuits for construction or failure proof, for frequencies 50 / 60Hz, built according to the European standard EN61558-2-6 which guarantees a product of guaranteed quality and reliability, use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production. The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. The peculiar features of the EI30 series: Wide range: pinout (your choice) primary voltage (optionally from 24V up to 440V) secondary voltage (optionally from 4V to 48V) · Possibility of distributing the total power up to 2 secondaries · Flexibility on the quantities that can be ordered Dimensions Menu EI 30 EI 33 EI 38 10 PINS EI 38 12 PINS EI 40 EI 42 E I 48 EI 54 EI 60 EI 66 EI 75 EI 84 ​ Examples Documents ei30.pdf

  • UI3913 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    Resinated Transformers UI 39/13 18 VA / Products / Resinated Transformers / Resinated Transformers UI / UI3913 Transformers mod. UI with a 2 X 115 V double primary circuit for 230 V series connection or 115 V + 115 V parallel connection. Possibility of fixing through pins or through 4 DIN 7971 2.4 mm holes. built according to the European standard EN61558-2-6 which guarantees a product of quality and reliability ensured not only by the use of excellent materials but also by the constant construction methodology and by our testing systems applied to the entire production. The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. Dimensions Documents Menu UI 30/7,5 UI 30/10 UI 30/16 UI 39/10 UI 39/13 UI 39/17 UI 39/21 UI 48/17 UI 48/26 ​ ​ Examples

  • Resinated | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    / Products / Resinated Transformers Trasformatori Resinati Resinati EI Resinati UI Resinati RG Resinated Transformers Transformers with resin insulation, from Printed Circuit, with Faston connection, Low Profile. Thanks to their construction and being encapsulated with self-extinguishing epoxy resin, they have additional insulation, which improves the safety of the equipment. All the products highlighted below are examples of our productions, for every need contact us directly in order to create the right product for your project. Products FROM "EI" PRINTED CIRCUIT Printed circuit resin transformers EI models from 1 to 100 VA. VIEW MORE FROM "UI" PRINTED CIRCUIT Low Profile Printed Circuit Transformers from 4 to 60 VA. VIEW MORE FASTON CONNECTION FASTON resin-coated transformers with lateral container and faston cover option. VIEW MORE DIN BAR FIXING Resin-coated transformers predisposed for fixing in an electrical panel DIN bar. VIEW MORE

  • EI66RG | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    Transformers EI 66R FROM 25 TO 55 VA / Products / Resinated Transformers / Resinated Transformers RG / EI66RG The items of the EI66RG series are safety transformers, not resistant to short circuits by construction, for 50 / 60Hz frequencies, built according to the European standard EN61558-2-6 which guarantees a product of guaranteed quality and reliability as well as by the use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production. The epoxy resin construction guarantees greater mechanical strength and better resistance to external agents as well as allowing insulation between the active parts greater than 4KV thanks also to the use, for the windings, of supports with separate chambers. The peculiar features of the EI66RG series: Wide range: pinout (your choice) primary voltage (optionally from 24V up to 440V) secondary voltage (optionally from 4V to 48V) · Possibility of distributing the total power up to 4 secondaries · Flexibility on the quantities that can be ordered Dimensions Menu EI 60 RG EI 66 RG EI 75 RG EI 84 RG ​ ​ ​ Documents EI66R.pdf Examples

  • EI84M2 | TRASFORMATORI VM|PRODUZIONE TRASFORMATORI ELETTRICI STANDARD E PERSONALIZZATI

    Transformers EI 84/2 FROM 63 TO 120 VA / Products / Control Transformers / EI84M2 The items of the EI84 MORSETTI series are control transformers, not resistant to short circuits with terminals mounted directly on the plastic reel, built according to the European standard EN61558-2-2 which guarantees a product of guaranteed quality and reliability as well as the use of excellent materials also from the constant construction methodology and from our testing systems applied to the entire production. To protect the transformers from overloads or short circuits, it is envisaged that protection devices (fuses) not supplied with the transformer, of the value indicated on the plate, must be used. The peculiar characteristics of the EI84 TERMINAL series: Primary voltage (optionally from 115V up to 400V) secondary voltage (optionally from 12 to 48V) · Possibility of distributing the total power on two secondaries · Flexibility on the quantities that can be ordered Dimensions Documents ei84M2.pdf Menu EI 75 30/63 EI 75M 30/63 EI 75M2 30/63 EI 84 63/120 EI 84M 63/120 EI 84M2 63/120 EI 96 ​ ​ ​ Examples

bottom of page